果冻视频

Filtered Results: 17 Products
  • FD-150X12

    Static Rated Fire Damper with Integral Sleeve

    Model FD-150X12 is a static-rated fire damper for walls, floors, and partitions with ratings under three hours, featuring an integral 12-inch sleeve to simplify installation. Designed for systems that shut down in a fire, it ensures reliable closure to maintain barrier integrity and meet life safety codes.

    • Up to 212掳F
    • Integral 12-inch sleeve
  • FD-150X16

    Static Rated Fire Damper with Integral Sleeve

    Model FD-150X16 is a static-rated fire damper for walls, floors, and partitions with ratings under three hours, featuring an integral 16-inch sleeve to simplify installation. Designed for systems that shut down in a fire, it ensures reliable closure to maintain barrier integrity and meet life safety codes.

    • Up to 212掳F
    • Integral 16-inch sleeve
  • FD-150

    Static Rated Fire Damper

    Model FD-150 is a static-rated fire damper for walls, floors, and partitions with ratings under three hours. Designed for systems that shut down in a fire, it ensures reliable closure to maintain barrier integrity and meet life safety codes.

    • Up to 212掳F
  • DFD-150X12

    Dynamic Rated Fire Damper with Integral Sleeve

    Dynamic-rated fire damper for walls, floors, or partitions under 3-hour ratings. Integral 12-in sleeve simplifies installation; closes under airflow in operational HVAC systems.

    • Up to 4 in. wg
    • Up to 4000 fpm
    • Up to 286掳F
  • DFD-150X16

    Dynamic Rated Fire Damper with Integral Sleeve

    Dynamic-rated fire damper for walls, floors, or partitions under 3-hour ratings. Integral 16-in sleeve simplifies installation; closes under airflow in operational HVAC systems.

    • Up to 4 in. wg
    • Up to 4000 fpm
    • Up to 286掳F
  • DFD-150

    Dynamic Rated Fire Damper

    Dynamic-rated fire damper for walls, floors, or partitions under 3-hour ratings. 3-11/16 in. frame depth fits standard assemblies; closes under airflow in operational HVAC systems.

    • Up to 4 in. wg
    • Up to 4000 fpm
    • Up to 286掳F
  • DFDR-510

    Dynamic Rated Round Fire Damper

    Round dynamic fire damper for walls, floors, or partitions under 3-hour ratings. Closes under airflow in operating HVAC systems, preserving rated assembly integrity in circular ducts.

    • Up to 4 in. wg
    • Up to 2000 fpm
    • Up to 286掳F
  • DFD-350

    Dynamic Rated Fire Damper

    Dynamic-rated fire damper for walls, floors, or partitions rated 3 hours or greater. 3-11/16 in. frame depth integrates into rated assemblies; closes under airflow in operating HVAC systems.

    • Up to 4 in. wg
    • Up to 4000 fpm
    • Up to 286掳F
  • DFD-110

    Dynamic Rated Fire Damper

    Dynamic-rated fire damper for walls, floors, or partitions under 3-hour ratings. Compact 2-3/16 in. frame depth supports integration in tight assemblies.

    • Up to 4 in. wg
    • Up to 4000 fpm
    • Up to 286掳F
  • DFD-310

    Dynamic Rated Fire Damper

    Dynamic-rated fire damper for walls, floors, or partitions rated 3 hours or greater. Compact 2-3/16 in. frame integrates into rated assemblies; closes under airflow in operating HVAC systems.

    • Up to 4 in. wg
    • Up to 4000 fpm
    • Up to 286掳F
  • FD-110

    Static Rated Fire Damper

    Static-rated fire damper for walls, floors, or partitions under 3-hour ratings. 2-3/16 in. frame depth; designed for HVAC systems that shut down during fire events.

    • Up to 212掳F
  • FD-310

    Static Rated Fire Damper

    Model FD-310 is a static-rated fire damper for walls, floors, and partitions with ratings of three hours or greater. Its compact 2-3/16 in. frame integrates into rated assemblies and ensures reliable closure to maintain barrier integrity and meet life safety codes.

    • Up to 212掳F
  • FD-350

    Static Rated Fire Damper

    Model FD-350 is a UL 555 Classified, static-rated fire damper for walls, floors, and partitions with ratings of three hours or greater. Its 3-11/16 in. frame provides robust construction and reliable closure to maintain barrier integrity and meet life safety codes.

    • Up to 212掳F
  • DFD-210

    Multi-Blade Fire Damper

    Multi-blade 3V dynamic fire damper for walls, floors, or partitions under 3-hour ratings. Closes under airflow in operating HVAC; low pressure drop supports efficient operation.

    • Up to 10 in. wg
    • Up to 4000 fpm
    • Up to 350掳F
  • DFDAF-310

    Multi-Blade Fire Damper

    Multi-blade airfoil dynamic fire damper for walls, floors, or partitions under 3-hour ratings. Closes under airflow in operating HVAC; airfoil blades reduce pressure drop.

    • Up to 8 in. wg
    • Up to 4000 fpm
    • Up to 350掳F
  • DFDAF-330

    Multi-Blade Fire Damper

    Multi-blade airfoil dynamic fire damper for walls, floors, or partitions rated 3 hours or greater. Closes under airflow in operating HVAC; low pressure drop supports efficient performance.

    • Up to 8 in. wg
    • Up to 4000 fpm
    • Up to 350掳F
  • ODFD-150

    Out of Wall Dynamic Rated Fire Damper

    Out-of-wall fire damper for walls or partitions with less than 3-hour fire-resistance ratings. Dynamic-rated for HVAC systems that remain operational during a fire.

    • Up to 4 in. wg.
    • Up to 4,000 fpm
    • Up to 212掳F
  • OFD-150

    Out of Wall Static Rated Fire Damper

    Out-of-wall fire damper for HVAC systems that shut down during a fire. Rated for walls or partitions with less than 3-hour fire-resistance ratings.

    • Up to 212掳F
  • SSFD-150

    Stainless Steel Static Rated Fire Damper

    304 stainless steel static fire damper with 3-11/16 in. (94 mm) frame for walls or partitions under 3-hour ratings. For HVAC systems that shut down during a fire.

    • Up to 212掳F
  • SSFD-350

    Stainless Steel Static Rated Fire Damper

    304 stainless steel static fire damper with 3-11/16 in. (94 mm) frame for walls or partitions with 3-hour or greater ratings. For HVAC systems that shut down during a fire.

    • Up to 212掳F
  • SSDFD-150

    Stainless Steel Dynamic Rated Fire Damper

    304 stainless steel fire damper with 3-11/16 in. (94 mm) frame for walls or partitions under 3-hour ratings. Dynamic-rated for HVAC systems operating during a fire.

    • Up to 4 in. wg
    • Up to 2,000 fpm
    • Up to 286掳F
  • SSDFD-350

    Stainless Steel Dynamic Rated Fire Damper

    304 stainless steel fire damper with 3-11/16 in. (94 mm) frame for walls or partitions with 3-hour or greater ratings. Dynamic-rated for HVAC systems operating during a fire emergency.

    • Up to 4 in. wg
    • Up to 2,000 fpm
    • Up to 286掳F
  • SEDFD-210

    Severe Environment Multi-Blade Fire Damper

    316 stainless steel 3V multi-blade fire damper for walls, floors, or partitions under 3-hour ratings. Dynamic-rated for HVAC systems that remain operational during a fire.

    • Up to 10 in. wg
    • Up to 4,000 fpm
    • Up to 350掳F
  • SSDFDR-510

    Round Stainless Steel Dynamic Rated Fire Damper

    304 stainless steel round fire damper for walls, floors, or partitions under 3-hour ratings. Dynamic-rated for HVAC systems operating during a fire.

    • Up to 4 in. wg
    • Up to 2,000 fpm
    • Up to 286掳F